TOUCH FX-400

The TOUCH FX-400 Electrosurgical Unit (ESU) represents cutting-edge technology in surgical instruments. Specifically engineered for precision and reliability, it offers surgeons a versatile tool for various electrosurgical procedures. Its intuitive interface and ergonomic design facilitate ease of use, ensuring precise control and minimal user fatigue during operations. Equipped with advanced safety features, including smoke evacuation capabilities and impedance monitoring, it prioritizes patient safety.

5
SURE PRECISE SEAL
5
ELECTROSURGERY THROUGH TECHNOLOGY
5
INTEL TISSUE RESPONSE
5
TOUCH SCREEN100-USER PROGRAM
MODES
MAXIMUM P-P VOLTAGE
RATED LOAD (OHMS)
MAXIMUM POWER (WATTS)
CREST FACTOR (TYPICAL)
Monopolar Cut
Pure
Blend I
Blend II
Blend III
Blend IV
900
1100
1200
1300
1300
500
500
500
500
500
400
300
250
200
150
1.5
2.1
2.4
2.8
3.1
Monopolar Coag.
Soft
Dessicate
Force
Spray
1600
1800
2100
3500
500
500
500
500
300
250
200
120
3.5
3.8
4.2
6.8
Bipolar
Micro
Standard
Macro/Cut
320
460
600
100
100
100
70
90
120
1.5
1.5
1.5
 VESSEL SEALING MODE: Pure Sine wave 440 kHz

Seal-Pulse output mode,
Soft-Seal 120 W at 100Ω     CF1.5
Med-Seal 200 W at 100Ω   CF1.5
Rapid-Seal 350 W at 100Ω CF1.5

PPQM System

Measuring Frequency: 85 kHz ± 10 kHz Measuring current: < 10 μα
Dual Area Patient Return Electrode: 5-135Ω
Single Area Patient Return Electrode: < 10Ω

Applications Fields

Opthalmic, Laparo Surgery, Endo, Gl, Ortho, Open & General Surgery, Onco, Gynecology, Hernia, GI Endocut, Papillotomy, Polypectomy, Under Water, Urology, Gynec TCRE, Hysteroscopy, Thoracotomy, Unit is suitable for all kind of Open, Endoscopic, Laparoscopic and Minimally Invasive Surgery Plastic, Neuro, ENT, Spine, Thoracic and Cardiac Surgery.

Safety Standards

Classification according to the EC- Directive 93/42/EEC: Class Ilb
General Safety Standards: IEC 60601-1-1, IEC 60601-2-2
EMI/EMC Compatibility Standard: IEC 60601-1-2
IS Safety Standard: 15 7583

Leakage Current

HF Leakage Monopolar <100 mA RMS Bipolar <50 mA RMS
Low frequency : Normal polarity,intact ground < 10μA
                               Normal polarity, ground open < 50μA

INPUT POWER

Operating Voltage: 190-260 Volt 50Hz AC, (Optional 90-120Volts 60Hz AC)

DIMENSIONS LXWXH-350 x 350 x 130mm Net Weight in 6.5 Kg